1997 / 2001 Dry spray agglomeration
|
|
During the years 1997 - 2001 Dipl.-Ing. Michael Kaden has developped the dry spray agglomeration system to enhance the effficiency of dust collection in gas cleaning plants.
In the meantime, this system is patented.
|
|
|
|
The basic component of this system are relatively simple spray lances which are equipped with specialised water spray nozzles. |
|
|
|
Reference plants | |
|
|
PG Bison Stellenbosch
South Africa
chip dryer for the wood panel production
flue gas cleaning with alera high efficiency cyclones
particle emission
without dry spray agglomeration
= 120 mg/Nm3
with dry spray agglomeration
= 20 mg / Nm3
Year of commissioning = 2000
|
|
|
|
Transvaal Sugar Board – Malelane
South Africa
Steam boiler 160 t/h with sugar cain waste and coal firing.
flue gas particulate loading = 5000 mg/Nm3 with 20 % < 5 µm particle size.
gas clean up with wet scrubber
emission without dry spray agglomeration = 380 mg/Nm3
emission with dry spray
agglomeration = 85 mg/Nm3
year of commissioning = 2001
|