1997 / 2001 Dry spray agglomeration

 
 
During the years 1997 - 2001 Dipl.-Ing. Michael Kaden has developped the dry spray agglomeration system to enhance the effficiency of dust collection in gas cleaning plants.
 
In the meantime, this system is patented.
 
 

The basic component of this system are relatively simple spray lances which are equipped with specialised water spray nozzles.

 

 

Reference plants
 
 
PG Bison Stellenbosch
 
South Africa
 
chip dryer for the wood panel production
flue gas cleaning with alera high efficiency cyclones
 
particle emission
 
without dry spray agglomeration
= 120 mg/Nm3
 
with dry spray agglomeration
= 20 mg / Nm3
 
Year of commissioning = 2000
 
 
Transvaal Sugar Board – Malelane 
 
South Africa
 
Steam boiler 160 t/h with sugar cain waste and coal firing.
 
flue gas particulate loading = 5000 mg/Nm3 with 20 % < 5 µm particle size.
 
gas clean up with wet scrubber
 
emission without dry spray agglomeration = 380 mg/Nm3 
 
emission with dry spray
agglomeration = 85 mg/Nm3
 
year of commissioning = 2001